AC prenapetostna zaščitna naprava 275VAC T2 tipa 20-40KA
Opis izdelka
AC SPD se primerno uporablja v napajalnih sistemih TT, TN-S, TN-C, IT, TN-C-S itd. AC 50/60Hz,<380V, installation om the joint of LPZ1 or LPZ2 and LPZ3, it adopts 35mm standard rail, there is a failure release mounted in the module of surge protection device. When the SPD fails in breakdown for over-hart and over-current, the failure release will help electric equipment separate from the power supply system and give the indication signal, green means normal, red means abnormal, it also could be replaced for the module when has operating voltage.
|
Tehnični parametri |
FSP-A |
|||||
|
Nazivna delovna napetost Un(V~) |
380V/220V |
|||||
|
Največja neprekinjena delovna napetost Uc(V~) |
275V |
320V |
385V |
385V |
385V |
420V |
|
Napetostna zaščita Level Up(V~)kV |
Manjše ali enako 1,0 |
Manjše ali enako 1,2 |
Manjši ali enak 1,8 |
Manjše ali enako 2,0 |
Manjši ali enak 2,2 |
Manjši ali enak 2,8 |
|
Nazivni izpustni tok ln (8/20s)kA |
5 |
10 |
20 |
30 |
40 |
60 |
|
Največji tok praznjenja lmax(8/20s)kA |
10 |
20 |
40 |
60 |
80 |
100 |
|
Odzivni čas (ns) |
<25 |
|||||
|
Testni standard |
IEC61643.1, GB18802.1 |
|||||
|
Delovno okolje (C) |
-40 stopinj ~+85 stopinj |
|||||
|
Največja priključna linija |
35 mm2 trda žica/35 mm2 pramenska žična bakrena linija |
|||||
|
Priporočena priključna linija |
16 mm2 trda žica/25 mm2 pramenska žična bakrena linija |
|||||
|
Namestitev |
Standardna tirnica 35 mm |
|||||
|
Material zunanje obloge |